Lesson 5: When redundancy disappoints

In this lesson

You will learn:

  • the two assumptions behind the parallel formula of Lesson 2, and what happens when real redundancy breaks them,
  • how cold, warm and hot standby compare with active redundancy, and what an imperfect switch costs,
  • why units that share a load fail sooner,
  • how a common cause puts a floor under a redundant group's unreliability (the beta-factor model),
  • how to compute each case with StandbyModel, LoadSharingModel and CCFGroup, and the pitfalls of each.

Before you start: Lesson 1 (exponential lifetimes and MTTF) and Lesson 2 (series, parallel and k-out-of-n). About 35 minutes.

The question

In Lesson 2 two pumps in parallel, each failing with probability \(q = 0.1\), failed together with probability \(q^2 = 0.01\): ten times less often than one pump. That multiplication hides two assumptions. Both pumps run all the time (active redundancy), and they fail independently: knowing that one has failed tells you nothing about the other.

Real redundancy often breaks one of them. The second pump may wait switched off until it is needed, so it does not wear, but something must then detect the failure and switch it in. The pumps may share the flow, so that when one fails the other runs at full load and wears faster. And two pumps of the same model, from one batch, in one room, serviced by one technician, can be stopped together by a single cause.

This lesson works out how much of the benefit of redundancy each case adds or takes away. The code on this page uses these imports:

import numpy as np
import surpyval as surv
from repyability import (
    BetaFactor,
    CCFGroup,
    LoadSharingModel,
    NonRepairableRBD,
    RegressionNode,
    StandbyModel,
)

A spare that waits: standby redundancy

Cold standby

Look at the active pair first. Both pumps start at time zero and both age, so when the first fails the survivor is not new. The pair's life is the longer of the two lifetimes, \(\max(T_1, T_2)\).

In cold standby the second pump is off and does not age while it waits. When the running pump fails, a switch (whatever detects the failure and starts the spare: a controller, a changeover valve, an operator) brings the spare in, and its life starts then. With a switch that always works, the pair's life is the sum \(T_1 + T_2\), never shorter than the longer of the two.

flowchart LR
    s((in)) --> a["pump A, running"] --> t((out))
    s --> sw{{switch}} -.-> b["pump B, off until needed"] -.-> t

The dotted path carries the flow only after pump A has failed, and only if the switch works.

The formula. Take two identical units with exponential lives of rate \(\lambda\) (a constant hazard, and an MTTF of \(1/\lambda\); see Lesson 1) and a perfect switch. The pair survives to time \(t\) if the first unit survives, or if it fails at some earlier time \(s\) and the spare survives the remaining \(t - s\):

\[ R(t) = e^{-\lambda t} + \int_0^t \underbrace{\lambda e^{-\lambda s}}_{\text{A fails at } s}\, \underbrace{e^{-\lambda (t - s)}}_{\text{B survives the rest}}\,ds = e^{-\lambda t} + \lambda t\, e^{-\lambda t} = e^{-\lambda t}(1 + \lambda t). \]

The integrand equals \(\lambda e^{-\lambda t}\) whatever \(s\) is, so the integral is \(\lambda t\, e^{-\lambda t}\). Equivalently, while one unit runs at a time failures arrive at the constant rate \(\lambda\), so their number by time \(t\) is Poisson with mean \(\lambda t\), and the pair survives if it is 0 or 1.

The mean life follows from \(T_1 + T_2\). Beside it, the active pair's from Lesson 2:

\[ \text{MTTF}_{\text{cold}} = \frac{1}{\lambda} + \frac{1}{\lambda} = \frac{2}{\lambda}, \qquad \text{MTTF}_{\text{active}} = \frac{1}{2\lambda} + \frac{1}{\lambda} = \frac{1.5}{\lambda}. \]

Read both as two stages. While both active units run, failures come at the combined rate \(2\lambda\), so the first arrives after \(1/(2\lambda)\) on average; the survivor, which has no memory of its age, lasts another \(1/\lambda\). The cold pair has only one unit exposed in its first stage, so that stage lasts \(1/\lambda\). That is the whole advantage of standby: fewer units exposed at once.

Units with an MTTF of 100 h have \(\lambda = 0.01\) per hour. At \(t = 100\) h, \(\lambda t = 1\):

  • one unit: \(e^{-1} = 0.3679\),
  • active pair: \(1 - (1 - e^{-1})^2 = 0.6004\),
  • cold standby: \(e^{-1}(1 + 1) = 0.7358\).

The MTTFs are 100 h, 150 h and 200 h.

unit = surv.Exponential.from_params([0.01])   # MTTF 100 h
pair_edges = [("s", "a"), ("s", "b"), ("a", "t"), ("b", "t")]
active = NonRepairableRBD(pair_edges, {"a": unit, "b": unit})
cold = StandbyModel([unit, unit])   # one running, one cold spare

active.sf(100)   # -> 0.6004
cold.sf(100)     # -> 0.7358
cold.mean()      # -> 200.0

A StandbyModel takes the units in the order they will be used and makes the arrangement, switch included, one node for any RBD. By default one unit works at a time (k=1), the switch is perfect (switching_probability=1.0) and the spare is cold (dormancy_factor=0). For identical exponential units and a perfect switch it uses the formula above (the Erlang distribution), so these numbers are exact. Over 100 h the cold pair fails with probability 0.264 and the active pair with 0.400: a third fewer failures from the same two pumps.

An imperfect switch

The spare helps only if the switch works when called on. If it works with probability \(p\), the second term of \(R(t)\) is multiplied by \(p\):

\[ R(t) = e^{-\lambda t}\,(1 + p\,\lambda t), \qquad \text{MTTF} = \frac{1 + p}{\lambda}. \]

With \(p = 0.9\) at 100 h, \(R = e^{-1}(1 + 0.9) = 0.6990\) and the MTTF is 190 h: still better than the active pair. On a short mission the picture changes. For small \(\lambda t\) the failure probabilities \(F(t) = 1 - R(t)\) are approximately

\[ F_{\text{active}} \approx (\lambda t)^2, \qquad F_{\text{standby}} \approx (1 - p)\,\lambda t + \left(p - \tfrac{1}{2}\right)(\lambda t)^2 . \]

A perfect switch (\(p = 1\)) halves the active pair's \((\lambda t)^2\), but a switch that can fail adds a term in \(\lambda t\) itself, far larger than \((\lambda t)^2\) when \(\lambda t\) is small.

At \(t = 10\) h, \(\lambda t = 0.1\):

lt = 0.01 * 10                     # λt at 10 h
1 - np.exp(-lt) * (1 + 0.9 * lt)   # -> 0.0137   standby, p = 0.9
1 - np.exp(-lt) * (1 + lt)         # -> 0.0047   standby, perfect switch
(1 - np.exp(-lt)) ** 2             # -> 0.0091   active pair

The approximations give \(0.01 + 0.4 \times 0.01 = 0.014\), \(0.005\) and \(0.01\).

switch90 = StandbyModel([unit, unit], switching_probability=0.9)
switch90.sf(100)   # -> 0.699    the formula gives 0.6990
switch90.mean()    # -> 190.0    the formula gives 190

With an imperfect switch the library cannot use the Erlang formula: it convolves the lifetimes numerically on a time grid. That works for any lifetime model and is repeatable, and here it agrees with the formula to within about 0.00000003.

At 10 h the standby pair with a 90% switch fails more often than the active pair (0.0137 against 0.0091), although over 100 h it is clearly better.

Warm and hot standby

Many spares are neither off nor fully working: a generator kept warm, a pump left idling. Such a warm spare ages while it waits, more slowly than when it works. The dormancy factor \(\kappa\) (dormancy_factor) is the ratio: a waiting spare ages at \(\kappa\) times the operating rate. \(\kappa = 0\) is cold standby; \(\kappa = 1\) is hot standby, where the spare ages as fast as the running unit: the active pair again. A warm spare can fail while it waits (a dormant failure), unnoticed until it is needed; the library then skips it.

The stage picture covers all three. In stage 1 the running unit fails at rate \(\lambda\) and the waiting spare at \(\kappa\lambda\), so the first failure comes at rate \((1 + \kappa)\lambda\). Then one unit is left, at rate \(\lambda\) (the exponential has no memory, so it does not matter which one failed):

Arrangement Rate of the first failure Mean of stage 1 Mean of stage 2 MTTF, \(\lambda = 0.01\)
Active, or hot (\(\kappa = 1\)) \(2\lambda\) \(1/(2\lambda)\) \(1/\lambda\) 150 h
Warm (\(\kappa = 0.5\)) \(1.5\lambda\) \(1/(1.5\lambda)\) \(1/\lambda\) 166.7 h
Cold (\(\kappa = 0\)) \(\lambda\) \(1/\lambda\) \(1/\lambda\) 200 h

The same integral as before, with the first failure at rate \((1 + \kappa)\lambda\), gives

\[ R(t) = e^{-\lambda t}\,\frac{(1 + \kappa) - e^{-\kappa\lambda t}}{\kappa}, \qquad 0 < \kappa \le 1, \]

which is the active pair's \(2e^{-\lambda t} - e^{-2\lambda t}\) at \(\kappa = 1\) and tends to \(e^{-\lambda t}(1 + \lambda t)\) as \(\kappa \to 0\). At 100 h with \(\kappa = 0.5\): \(e^{-1}(1.5 - e^{-0.5})/0.5 = 0.6574\).

warm = StandbyModel([unit, unit], dormancy_factor=0.5)
hot = StandbyModel([unit, unit], dormancy_factor=1.0)
warm.sf(100)    # -> 0.6574
warm.mean()     # -> 166.67
hot.sf(100)     # -> 0.6004   the active pair

For identical exponential units the library uses exactly these stages (the hypoexponential distribution), so the results are exact. How much does a little dormant ageing cost?

kappas = [0, 0.25, 0.5, 0.75, 1]
[round(StandbyModel([unit, unit], dormancy_factor=kappa).mean(), 1) for kappa in kappas]
# [200.0, 180.0, 166.7, 157.1, 150.0]
xychart-beta
    title "MTTF of a standby pair of units with MTTF 100 h"
    x-axis "dormancy factor" ["0", "0.25", "0.5", "0.75", "1"]
    y-axis "MTTF (h)" 0 --> 200
    line [200, 180, 166.7, 157.1, 150]

The curve falls fastest at the start: a spare ageing at a quarter of the operating rate already gives up 20 of the 50 hours that cold standby gains over the active pair.

Comparing the arrangements

t = np.array([10, 50, 100, 200])
for name, model in [("one unit", unit), ("active", active), ("cold", cold),
                    ("cold, p=0.9", switch90), ("warm, 0.5", warm)]:
    print(f"{name:12}", np.round(model.sf(t), 3))
# one unit     [0.905 0.607 0.368 0.135]
# active       [0.991 0.845 0.6   0.252]
# cold         [0.995 0.91  0.736 0.406]
# cold, p=0.9  [0.986 0.879 0.699 0.379]
# warm, 0.5    [0.993 0.875 0.657 0.306]
\(t\) (h) \(\lambda t\) One unit Active pair Cold standby Cold, \(p = 0.9\) Warm, \(\kappa = 0.5\)
10 0.1 0.905 0.991 0.995 0.986 0.993
50 0.5 0.607 0.845 0.910 0.879 0.875
100 1 0.368 0.600 0.736 0.699 0.657
200 2 0.135 0.252 0.406 0.379 0.306
MTTF (h) 100 150 200 190 166.7
  • Cold standby with a perfect switch is the best at every time: never more than one unit is exposed.
  • The warm spare sits between cold standby and the active pair.
  • The imperfect switch costs little late in life, but at 10 h it is the worst pair of all.

How StandbyModel gets its answer depends on the case:

Arrangement Method
Identical exponential units, perfect switch, any \(\kappa\) Exact formula
Hot (\(\kappa = 1\)), any units Exact: \(k\)-out-of-\(n\)
Cold, one unit working at a time (k=1): any lifetimes, any switch Numerical convolution: repeatable, accurate to a few decimals
Cold, k=2 or more identical units working together Numerical: renewal counts of the working positions
Cold, k=2, any units Numerical: a recursion over the switch-ins
Warm, one unit working at a time: any lifetimes Numerical: a recursion over the switch-ins
Anything else: warm with k=2 or more, or k=3 or more different units working together, cold Simulation: pass seed=0 for repeatable results; sf then returns a one-element array

An imperfect switch is supported for cold standby. The guide has every option.

Wearing-out units gain even more

The running example's pumps wear out (Weibull, with scale 100 h and shape 2). A cold spare starts new at the moment the first pump is worn out, so at 150 h the cold pair survives with probability 0.634 against 0.200 for the active pair.

pump = surv.Weibull.from_params([100, 2])
NonRepairableRBD(pair_edges, {"a": pump, "b": pump}).sf(150)   # -> 0.1997
StandbyModel([pump, pump]).sf(150)                            # -> 0.6342

A shared load

Now let redundant units share the work. Three pumps each carry a third of the flow, and the system needs any two. When one fails, the other two carry half each instead of a third; working harder, they wear faster and fail sooner. Each failure brings the next closer, so the redundancy is worth less than the k-out-of-n formula of Lesson 2 says.

flowchart LR
    three["3 pumps working<br>each carries 1.0"] -- "first failure" --> two["2 pumps working<br>each carries 1.5"]
    two -- "second failure" --> down["1 pump left:<br>the group has failed"]

To model this you need a unit's life as a function of its load. An accelerated-failure-time (AFT) model says that load speeds up the unit's clock: under load \(\ell\) it ages \(\phi(\ell)\) times as fast as its baseline, so its life is divided by \(\phi(\ell)\). The model is fitted in surpyval to lives observed at several loads; RePyability takes the fitted model. With the guide's illustrative data:

# Illustrative field data: lives at various loads (higher load, shorter life).
rng = np.random.default_rng(0)
load = rng.uniform(0.5, 2.0, size=800)
life = rng.exponential(scale=100.0 / np.exp(0.6 * (load - 1.0)), size=800)
unit_aft = surv.ExponentialAFT.fit(life + 1e-3, Z=load.reshape(-1, 1))   # surpyval's job

# Three units share a total load of 3.0; the group needs two.
group = LoadSharingModel([unit_aft, unit_aft, unit_aft], load=3.0, k=2)
group.sf(50)          # -> 0.5842
group.mean()          # -> 70.4
group.is_simulated    # False: exact for identical exponential units

A LoadSharingModel takes one fitted AFT model per unit, the total load \(L\), and k, the number of units the group needs; while \(s\) units survive, each carries \(L/s\). For identical exponential units the result is exact; otherwise it is simulated (pass seed).

By hand, the stage picture applies again. A RegressionNode holds a fitted regression model at a fixed load, so it gives one unit's mean life at each load:

at_1 = RegressionNode(unit_aft, covariates=[1.0])     # one unit at load 1.0
at_15 = RegressionNode(unit_aft, covariates=[1.5])    # one unit at load 1.5
at_1.mean()                          # -> 100.8
at_15.mean()                         # -> 73.5
at_1.mean() / 3 + at_15.mean() / 2   # -> 70.4   the group's MTTF, by stages

Three units at load 1.0 lose the first of their number after \(100.8/3 = 33.6\) h on average; the two survivors, now at load 1.5, lose the next after \(73.5/2 = 36.8\) h: 70.4 h in all, the library's value. An independent 2-out-of-3 group at the initial load (Lesson 2) would have had \(100.8/2 = 50.4\) h for the second stage:

p = at_1.sf(50)                   # one unit at load 1.0 survives 50 h
3 * p**2 - 2 * p**3                  # -> 0.6608   independent 2-out-of-3
at_1.mean() / 3 + at_1.mean() / 2    # -> 84.0

The load transfer lowers the 50 h reliability from 0.661 to 0.584 and the MTTF from 84.0 h to 70.4 h.

A common cause

One cause, every unit

Identical redundant units share more than a design: the same batch, the same room, the same (possibly contaminated) fluid, the same maintenance procedure and people. One such event, a common cause, can fail them all together, and against it redundancy gives no protection.

A shared part you can name, such as one power supply feeding both pumps, belongs in the diagram itself (see One component in several places). Common-cause models cover the many shared causes you cannot list one by one.

The beta-factor model

The beta-factor model splits each unit's failure probability \(q\) (over the mission, as in Lesson 2) in two. A fraction \(\beta\) comes from causes shared by the whole group, which fail every unit at once; the rest, \((1 - \beta)q\), is the unit's own, independent of the others. It is as if a shared-cause block sat in series with a parallel pair of own-cause blocks:

flowchart LR
    s((in)) --> a["pump A, own causes<br>fails with (1 − β)q"] & b["pump B, own causes<br>fails with (1 − β)q"]
    a & b --> c["shared cause<br>strikes with βq"] --> t((out))

The pair works if the shared cause does not strike and at least one pump survives its own causes. With \(Q_{\text{sys}} = 1 - R_{\text{sys}}\) the pair's failure probability:

\[ R_{\text{sys}} = (1 - \beta q)\left[1 - \big((1 - \beta)q\big)^2\right], \]
\[ Q_{\text{sys}} = \beta q + \big((1 - \beta)q\big)^2 - \beta q\,\big((1 - \beta)q\big)^2 . \]

The terms are the shared cause, both pumps failing from their own causes, and a correction for counting "both at once" twice. That correction is a product of small numbers, so for small \(q\)

\[ Q_{\text{sys}} \approx \beta q + \big((1 - \beta)q\big)^2 , \]

with a relative error below \(\beta q\) (under 0.1% whenever \(\beta q < 0.001\)). The shared term \(\beta q\) is the larger whenever \(\beta\) exceeds about \(q\) (exactly, \(\beta > (1 - \beta)^2 q\)): for good units, even a small \(\beta\) takes over.

With \(q = 0.01\) and \(\beta = 0.1\):

  • shared cause: \(\beta q = 0.001\),
  • own causes: \(\big((1 - \beta)q\big)^2 = 0.009^2 = 0.000081\),
  • overlap: \(0.001 \times 0.000081 = 8.1 \times 10^{-8}\),
  • \(Q_{\text{sys}} = 0.001 + 0.000081 - 0.00000008 = 0.001081\).

The independent model says \(q^2 = 0.0001\).

q, beta = 0.01, 0.1
1 - (1 - beta * q) * (1 - ((1 - beta) * q) ** 2)   # -> 0.001081
pump_q = surv.FixedEventProbability.from_params(0.01)   # q = 0.01
independent = NonRepairableRBD(pair_edges, {"a": pump_q, "b": pump_q})
common = NonRepairableRBD(
    pair_edges, {"a": pump_q, "b": pump_q},
    ccf_groups=[CCFGroup(["a", "b"], BetaFactor(0.1))],
)
independent.ff()   # -> 0.0001
common.ff()        # -> 0.001081

The common cause makes the pair about 11 times as likely to fail, and 93% of its failures are the shared cause. A CCFGroup names the coupled nodes and the model; NonRepairableRBD takes a list of groups as ccf_groups. The library conditions on whether each shared cause strikes, as the formula does, and evaluates each case exactly, so it returns the exact \(Q_{\text{sys}}\) above. BetaFactor(0) gives back the independent answer and BetaFactor(1) a pair no better than one pump. A group's members must carry identical models.

A third unit barely helps

Under independence each extra pump multiplies the failure probability by \(q\), a hundredfold gain here. Under the beta factor the shared cause fails every pump however many there are, so \(\beta q\) is a floor: for \(n\) pumps, \(Q_{\text{sys}} \approx \beta q + \big((1 - \beta)q\big)^n\).

def parallel_pumps(n, beta=None):
    """n pumps in parallel, each failing with probability 0.01."""
    names = [f"p{i}" for i in range(1, n + 1)]
    edges = [("s", name) for name in names] + [(name, "t") for name in names]
    groups = [CCFGroup(names, BetaFactor(beta))] if beta else None
    return NonRepairableRBD(edges, {name: pump_q for name in names}, ccf_groups=groups)

parallel_pumps(3).ff()             # -> 1e-06
parallel_pumps(3, beta=0.1).ff()   # -> 0.0010007
Pumps in parallel Independent Beta factor, \(\beta = 0.1\)
1 \(0.01\) \(0.01\)
2 \(1 \times 10^{-4}\) \(1.081 \times 10^{-3}\)
3 \(1 \times 10^{-6}\) \(1.0007 \times 10^{-3}\)
4 \(1 \times 10^{-8}\) \(1.0000 \times 10^{-3}\)

The third pump improves the pair by 7%, and the fourth by almost nothing. The defences against a common cause are different: lower \(\beta\) (separate the units, stagger their testing and maintenance) or add a diverse unit, of a different design, that does not share the cause.

The beta factor assumes a shared cause fails every unit. In a larger group some causes fail only some units (two pumps of three), which matters when the group needs more than one unit. The Multiple Greek Letter (MGL) model generalises the beta factor with a parameter per level (\(\gamma\) for the chance that a shared failure takes a third unit, and so on); see Common-cause failures.

Pitfalls

Independence flatters redundancy

For identical units the independence of Lesson 2 is optimistic, and more so the better the units and the more of them: with \(q = 0.01\) and \(\beta = 0.1\) the independent model was 11 times too optimistic for a pair and 1,000 times for a triple. Load sharing errs the same way (0.661 against 0.584 above).

β is an input you must justify

Take it from field data (the share of failures that hit more than one unit at once) or from a standard. IEC 61508-6, Annex D, scores a design's defences against common cause (separation, diversity, testing and so on) and turns the score into a \(\beta\) of 1% to 10% for sensors and final elements such as valves, and 0.5% to 5% for logic subsystems. Record where your \(\beta\) came from, and check how much the answer moves with it.

A spare must switch in, and must still work

The switch is in series with the spare, and on a short mission its failure dominates. A waiting spare can fail unseen: test it periodically, and model its dormant ageing with dormancy_factor instead of assuming it cold.

Split a probability only while q is small

By default the beta factor splits a probability, so use it over a mission or test interval where each unit's \(q\) stays small; RePyability warns once a unit's \(q\) passes 0.1. Over a whole life, split the failure rate, BetaFactor(beta, basis="rate"): the shared cause is a shock with reliability \(R(t)^\beta\) and each unit's own causes have \(R(t)^{1-\beta}\), so every unit keeps its own life, and the MTTF and the simulations include the group (see Over a lifetime).

Summary

Key ideas

  • The parallel formula assumes every unit runs all the time and fails independently; real redundancy often does neither.
  • Cold standby exposes fewer units at once. Two exponential units with a perfect switch give \(R(t) = e^{-\lambda t}(1 + \lambda t)\) and an MTTF of \(2/\lambda\), against \(1.5/\lambda\) active; a warm spare (dormancy factor \(\kappa\)) sits between the two.
  • A switch that works with probability \(p\) gives \(R(t) = e^{-\lambda t}(1 + p\lambda t)\): its failure adds a term in \(\lambda t\), which dominates short missions.
  • Units that share a load fail sooner together, as each failure loads the survivors; LoadSharingModel takes the load-dependent lifetime fitted in surpyval.
  • A common cause fails every unit at once. Under the beta factor, \(Q_{\text{sys}} \approx \beta q + \big((1 - \beta)q\big)^2\): once \(\beta\) exceeds about \(q\) the shared term dominates, and identical units cannot get below \(\beta q\).

Exercises

1. Two identical units have exponential lives with an MTTF of 500 h. Find the MTTF and the 500 h reliability of an active pair and of a cold-standby pair with a perfect switch.

Answer

\(\lambda = 0.002\) per hour, so \(\lambda t = 1\) at 500 h. Active: MTTF \(1.5/\lambda = 750\) h and \(R = 2e^{-1} - e^{-2} = 0.6004\). Cold: MTTF \(2/\lambda = 1000\) h and \(R = 2e^{-1} = 0.7358\).

unit500 = surv.Exponential.from_params([0.002])
StandbyModel([unit500, unit500]).mean()                       # -> 1000.0
StandbyModel([unit500, unit500]).sf(500)                      # -> 0.7358
StandbyModel([unit500, unit500], dormancy_factor=1.0).mean()  # -> 750.0   hot = active

2. The switch in exercise 1 works with probability 0.95. Find the MTTF and the 500 h reliability. Over a 25 h mission, which is more reliable: this standby pair or the active pair?

Answer

MTTF \(= 1.95/\lambda = 975\) h and \(R(500) = 1.95\,e^{-1} = 0.7174\), still above the active pair's 0.6004. Over 25 h (\(\lambda t = 0.05\)) the standby pair fails with probability \(1 - e^{-0.05}(1 + 0.95 \times 0.05) = 0.0036\) and the active pair with \((1 - e^{-0.05})^2 = 0.0024\). The active pair wins: the switch adds about \(0.05 \times 0.05 = 0.0025\), more than the cold spare saves.

switch95 = StandbyModel([unit500, unit500], switching_probability=0.95)
switch95.mean()     # -> 975.0    by hand: 975 (numerical convolution)
switch95.sf(500)    # -> 0.717
switch95.ff(25)     # -> 0.0036
NonRepairableRBD(pair_edges, {"a": unit500, "b": unit500}).ff(25)   # -> 0.0024

3. Two units in parallel each fail with probability \(q = 0.001\) over a mission, with \(\beta = 0.05\). What is the pair's failure probability with and without the common cause?

Answer

Independent: \(q^2 = 10^{-6}\). Beta factor: \(\beta q = 5 \times 10^{-5}\) plus \(0.00095^2 = 9.0 \times 10^{-7}\) gives \(Q_{\text{sys}} \approx 5.09 \times 10^{-5}\) (the overlap is negligible): 51 times the independent value, 98% of it the shared cause.

unit_q = surv.FixedEventProbability.from_params(0.001)
NonRepairableRBD(
    pair_edges, {"a": unit_q, "b": unit_q},
    ccf_groups=[CCFGroup(["a", "b"], BetaFactor(0.05))],
).ff()   # -> 5.09e-05

4. You add a third identical unit to the pair of exercise 3, in the same group. How much does it help, and why? What would help more?

Answer

\(Q_{\text{sys}} \approx 5 \times 10^{-5} + 0.00095^3 \approx 5.00 \times 10^{-5}\): 1.8% better than the pair, where independence would promise a thousandfold gain. The shared cause fails every unit, so \(\beta q\) is a floor. A diverse third unit, outside the group and sharing none of the pair's causes, gives \(5.09 \times 10^{-5} \times 0.001 \approx 5.1 \times 10^{-8}\).

triple = [("s", "a"), ("s", "b"), ("s", "c"), ("a", "t"), ("b", "t"), ("c", "t")]
same = {"a": unit_q, "b": unit_q, "c": unit_q}
NonRepairableRBD(
    triple, same, ccf_groups=[CCFGroup(["a", "b", "c"], BetaFactor(0.05))]
).ff()   # -> 5.00e-05
NonRepairableRBD(
    triple, same, ccf_groups=[CCFGroup(["a", "b"], BetaFactor(0.05))]
).ff()   # -> 5.1e-08   c is diverse: outside the group

5. Two pumps share a flow, and either can carry all of it alone. Each has an exponential life with a mean of 100 h at half the flow and 25 h at the full flow. Use the stage picture to find the pair's MTTF, and compare it with the MTTF you would get by ignoring the load transfer.

Answer

Stage 1: both pumps at half flow fail at \(2 \times 0.01 = 0.02\) per hour, a mean of 50 h. Stage 2: the survivor at full flow fails at \(1/25\) per hour, a mean of 25 h. The MTTF is 75 h: half the \(50 + 100 = 150\) h you would get by ignoring the transfer, though still three times one pump carrying the full flow (25 h).

1 / (2 * 0.01) + 1 / 0.04   # -> 75.0   sharing the load
1 / (2 * 0.01) + 1 / 0.01   # -> 150.0  ignoring the transfer

Where next

So far every failure has been final. Lesson 6 lets components be repaired and asks what fraction of the time the system is up.

Every option is in the guide: Redundancy models (standby with several working units, repeated nodes, load sharing) and Common-cause failures (the MGL model, and which methods honour a group). The theory is summarised in Concepts.